Description

The Fluke 117 True RMS digital multimeter is the perfect troubleshooting tool for "go/no go" non-contact voltage detection. It has a selectable low-impedance mode to prevent false readings from ghost voltage. Designed specifically for electricians.

FEATURES
> Non-contact voltage detection
> AutoVolt, automatic AC/DC voltage selection
> Safety-rated CAT III 600 V
> Maximum resolution is 1 milliamp
> True-RMS for accurate measurements on non-linear loads
> Measures 20A (30 seconds momentary; 10 A continuous)
> Measures resistance, continuity, frequency, capacitance, and min/max/average
> Large white LED backlight to work in poorly lit areas
> Provides Min/Max/Average with elapsed time to record signal fluctuations

SPECIFICATIONS
Max voltage 600V
Safety IEC 61010-2-033 CAT III 600 V
Digital display 6,000 count, updates 4 times per second
Bar graph 33 segments, updates 32 times per second
Typical battery life 400 hours without backlight

ACCURACY SPECIFICATIONS
DC millivolts range/resolution 600.0 mV / 0.1 mV
  Accuracy ± ([% of reading] + [counts]): 0.5% + 2
DC volts range/resolution 6.000 V / 0.001 V, 60.00 V / 0.01 V, 600.00 V / 0.1 V
  Accuracy ± ([% of reading] + [counts]): 0.5% + 2
Auto volts range/resolution 600.0 V / 0.1 V
  Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz), 4.0% + 3 (500 Hz to 1 kHz)
AC millivolts True RMS range/resolution 600.0 mV / 0.1 mV
  Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz), 2.0% + 3 (500 Hz to 1 kHz)
AC volts True RMS range/resolution 6.000 V / 0.001, V60.00 V / 0.01, V600.0 V / 0.1 V
  Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz), 2.0% + 3 (500 Hz to 1 kHz)
Continuity range/resolution 600 Ω / 1 Ω
  Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer
Ohms 
  Range/resolution 600.0 Ω / 0.1 Ω, 6.000 kΩ / 0.001 kΩ, 60.00 kΩ / 0.01 kΩ, 600.0 kΩ / 0.1 kΩ, 6.000 MΩ / 0.001 MΩ
  Accuracy 0.9% + 1
  Range/resolution 40.00 MΩ / 0.01 MΩ
  Accuracy 5% + 2
Diode test
  Range/resolution 2.00 V / 0.001 V
  Accuracy 0.9% + 2
Capacitance
  Range/resolution 1000 nF / 1 nF, 10.00 μF / 0.01 μF, 100.0 μF / 0.1 μF, 9999 μF / 1 μF, 100 μF to 1000 μF
  Accuracy 1.9% + 2
  Range/resolution > 1000 μF
  Accuracy 5% + 20%
Lo-Z capacitance Range 1 nF to 500 μF
  Accuracy 10% + 2 typical
AC amps True RMS (45 Hz to 500 Hz) 
  Range/resolution 6.000 A / 0.001 A, 10.00 A / 0.01 A
  Accuracy 1.5% + 3 20 A continuous overload for 30 seconds max
DC amps Range/resolution 6.000 A / 0.001 A, 10.00 A / 0.01 A
  Accuracy 1.0% + 3 20 A continuous overload for 30 seconds max
Hz (V or A input)² 
  Range/resolution 99.99 Hz / 0.01 Hz, 999.9 Hz / 0.1 Hz, 9.999 kHz / 0.001 Hz, 50.00 kHz / 0.01 Hz
  Accuracy 0.1% + 2

Battery powered 9 volt alkaline 6LR61
Size 167H x 84W x 46D mm
Weight 550g

WHAT YOU GET
Fluke 117 Digital Multimeter
Test leads with 4mm tips and protective caps
Holster
Battery 9V
User manual

Attachments

Fluke 117 Multimeter Data Sheet (Fluke_117_Multimeter_Data_Sheet.pdf, 354 Kb) [Download]

Fluke 110113114115117 Quick reference guide (Fluke_110113114115117__Quick_reference_guide.pdf, 4,884 Kb) [Download]

Fluke 114, 115, 116, and 117 DETAILED SPECIFICATIONS (DETAILED_SPECIFICATIONS_114,_115,_116,_117.pdf, 1,019 Kb) [Download]

Fluke 114, 115, 116, and 117 Calibration manual (Fluke_114,_115,_116,_and_117_Calibration_manual.pdf, 1,049 Kb) [Download]

Fluke 110113114115117 Users manual (Fluke_110113114115117__Users_manual.pdf, 1,177 Kb) [Download]